Ingersoll Rand heatless and heated blower desiccant air dryers from 5 to 14,900 m³/hr, delivering a constant -40 °C or -70 °C pressure dew point at up to 10 bar g. Microprocessor control with Modbus, an Energy Management System to cut regeneration costs, and high efficiency pre- and after-filters.
| Range | Heatless modular (DA5IM to DA300IM), heatless twin tower (D160ILA to D8500ILA), heated blower (D500IBA to D14900IBA) |
|---|---|
| Flow range | 5 to 14,900 m³/hr |
| Heatless twin tower | 2.8 to 55.9 m³/min |
| Heated blower | 8.9 to 248.6 m³/min |
| Pressure dew point | -40 °C or -70 °C (heatless), -40 °C (heated blower) |
| Max working pressure | 10 bar g continuous |
| Regeneration air | 15% (heatless), 0% (heated blower) |
| Controller | Digital microprocessor, Modbus compatible, 7 inch display on heated blower models |
| Filtration | Pre-filter to 0.01 mg/m³ oil aerosol, after-filter to 1 micron |
| Brand | Ingersoll Rand |
Ingersoll Rand desiccant air dryers cover flows from 5 to 14,900 m³/hr in three ranges: heatless modular dryers (DA5IM to DA300IM), heatless twin tower dryers (D160ILA to D8500ILA, 2.8 to 55.9 m³/min) and heated blower dryers (D500IBA to D14900IBA, 8.9 to 248.6 m³/min). All are rated for continuous 10 bar g operation and run at 50 Hz as standard.
Heatless dryers deliver a constant -40 °C or -70 °C pressure dew point and use 15% of the compressed air for regeneration. Heated blower dryers deliver -40 °C and use 0% purge air, regenerating the desiccant with a centrifugal blower and high-performance heater instead, which is why they suit larger installations where energy cost matters most. The Energy Management System (EMS) holds a constant dew point while matching regeneration to the actual load; it is standard on heated blower dryers and optional on heatless models.
A digital microprocessor controller monitors the dryer continuously, matches dryer control to the load and unload state of the compressor and is Modbus compatible, with a 7 inch display on heated blower models. High efficiency pre-filters remove oil aerosol down to 0.01 mg/m³ and heavy duty after-filters remove particles down to 1 micron. Heated blower dryers come as standard with an IP54 enclosure, soft starter, non-acidic desiccant, silencing muffler, butterfly valves, safety relief valve and humidity sensor, with IP65 enclosures, 60 Hz supply and pneumatic options available.
Harold Engineering supplies, installs and commissions Ingersoll Rand dryers and compressed air systems across Ireland from our Dublin and Galway bases, with 15 OEM trained field service engineers, genuine OEM spare parts and a 24 hour breakdown callout service.
| Range | Heatless modular (DA5IM to DA300IM), heatless twin tower (D160ILA to D8500ILA), heated blower (D500IBA to D14900IBA) |
|---|---|
| Flow range | 5 to 14,900 m³/hr |
| Heatless twin tower | 2.8 to 55.9 m³/min |
| Heated blower | 8.9 to 248.6 m³/min |
| Pressure dew point | -40 °C or -70 °C (heatless), -40 °C (heated blower) |
| Max working pressure | 10 bar g continuous |
| Regeneration air | 15% (heatless), 0% (heated blower) |
| Controller | Digital microprocessor, Modbus compatible, 7 inch display on heated blower models |
| Filtration | Pre-filter to 0.01 mg/m³ oil aerosol, after-filter to 1 micron |
| Brand | Ingersoll Rand |
Air Compressor, Vacuum Pump, Garage Equipment, Gas Heating & Dust/Fume Extraction Specialists