Products
Dublin 01 257 5100
Galway 091 795 900
sales@haroldeng.ie
A downdraft table pulls contaminated air DOWN through a perforated worktop and into a filter below, rather than trying to capture it from above or the side. For bench work like grinding, sanding or light welding, that downward pull tends to be far more effective than an overhead hood, because the operator isn’t standing in the airflow path.
Table size should match the largest workpiece you’re realistically handling, with some margin — a table that’s too small just pushes contaminated air past its edges instead of through it.
We supply and install downdraft tables sized to your bench work, with filtration specified for the material you’re processing.
The two tables in the range
The Nederman Welding and Grinding Table captures fume, dust and particles at source. It comes in 900, 1,350 and 2,000 mm sizes, with airflows from 1,000 to 4,000 m³/h depending on size. It takes a 500 kg distributed load, collects dust in a drawer that empties from the front, and connects through a duct on top to an external fan and filter unit. It suits welding and grinding, but not cutting.
The Plymovent DraftMax Ultra is a self-contained downdraft and backdraft table for heavy-duty welding and grinding. Its 2.2 kW fan moves 2,500 m³/h through two self-cleaning filter cartridges rated at over 99.9% efficiency, with three stages of spark protection and a 1,366 x 750 mm work grid.
The main choice between them is whether you want the table connected to a separate fan and filter, or everything built into the table itself. If you’re not sure which suits your workshop, we can look at the work you’re doing and recommend the right setup.